Capacitive humidity sensor KFS140-FA
€27.87
Delivery time: 2-3 working days after receipt of payment (advance payment) or conclusion of contract
| Description: | Capacitive humidity sensor |
|---|---|
| Operating temperature: | -50...+150 °C |
| Humidity measuring range: | 0...100% RH (max. dew point = +83 °C) |
| Response time humidity: | T63: < 1 s (50% RH to 0% RH at +23 °C) |
| Capacity: | 140 pF ±40 pF (at 23 °C and 30% RH) |
| Incline: | 0.25 pF/% RH |
| Frequency range: | 1...100 kHz |
| Hysteresis: | < ±1.5% RH |
| Dimensions: | (LxWxH) 5 x 3.81 x 0.4 / 0.8 mm |
| Connection: | Cu/Ag wire, 18 mm, AWG26, PTFE, insulated 8 mm |
| Signal form: | AC voltage without DC component |
| Operating voltage: | max. 12 Vpp AC |
| Loss factor: | < 0.01 |
| Weight: | 0.0001 kg |
The KFS140-FA humidity sensor has been developed as a custom made solution for application in radio probes and weather balloons.
Due to very good performance data and extremely fast response time, the sensor is also ideally suitable for applications in medical systems or in research and science.
Typical areas of application
- Meteorology
- Radio probes
- Medical systems
- Research and science
| Description: | Capacitive humidity sensor |
|---|---|
| Operating temperature: | -50...+150 °C |
| Humidity measuring range: | 0...100% RH (max. dew point = +83 °C) |
| Response time humidity: | T63: < 1 s (50% RH to 0% RH at +23 °C) |
| Capacity: | 140 pF ±40 pF (at 23 °C and 30% RH) |
| Incline: | 0.25 pF/% RH |
| Frequency range: | 1...100 kHz |
| Hysteresis: | < ±1.5% RH |
| Dimensions: | (LxWxH) 5 x 3.81 x 0.4 / 0.8 mm |
| Connection: | Cu/Ag wire, 18 mm, AWG26, PTFE, insulated 8 mm |
| Signal form: | AC voltage without DC component |
| Operating voltage: | max. 12 Vpp AC |
| Loss factor: | < 0.01 |
| Weight: | 0.0001 kg |
The KFS140-FA humidity sensor has been developed as a custom made solution for application in radio probes and weather balloons.
Due to very good performance data and extremely fast response time, the sensor is also ideally suitable for applications in medical systems or in research and science.
Typical areas of application
- Meteorology
- Radio probes
- Medical systems
- Research and science
Similar articles
Other customers also bought
We generally offer standard shipping via DPD. You can also pick up your order yourself or ship with your own tracking number. You can select the option you prefer during the ordering process.
You find more information about this topic on our rights of withdrawal page.
You can pay with PayPal, credit card (VISA and MaserCard), payment in advance, Sofortüberweisung (direct banking) and in some cases invoice. You can find more information on the page shipping and payment.
Yes, at B+B we can manufacture customised items for you with a minimum order value of €500.00.