Dew point controller for pipes | Ø 28-35 mm
€75.64
Delivery time: 1-2 weeks after receipt of payment (advance payment) or conclusion of contract
| Description: | Dew point controller |
|---|---|
| Measuring medium: | Ambient air (without admixtures) |
| Operating temperature: | 0...+60 °C |
| Humidity measuring principle: | Resistive dew sensor |
| Humidity measuring range: | 0...100% RH |
| Response time humidity: | approx. 30 s (when changing from 75% RH to condensation) |
| Switching characteristic: | Potential-free switching output (relay) 24 V AC, NO / NC contact selectable |
| Switching point: | 90% RH, ±4 % preset |
| Switching capacity: | 5A / 230 V AC; 5A / 30 V DC |
| Contact voltage: | 24 V AC |
| Contact resistance: | Closed: 100 Ω, open: > 1 MΩ |
| Switch display: | LED green (power); LED not lit (dry); LED red (condensation) |
| Condensation: | permitted |
| Condensation: | Permitted for a short time |
| Hysteresis: | approx. 4% |
| Pipe diameter: | Ø 28-35 mm |
| Dimensions: | (LxWxH) 65 x 60 x 42 mm (without mounting clamp, without cable) |
| Connection: | Push-in terminal 0.0509–1.31 mm² (16–30 AWG) |
| Output: | Switching relay |
| Operating current: | typ. 7 mA, max. 30 mA (relay active) |
| Operating voltage: | 24 V AC ±10%, 50 Hz or 24 V DC ±10% |
| Function check: | Rote Power LED leuchtet bei Betrieb |
| Protective filter: | Polyethylene sintered material |
| Type of protection: | IP65 |
| Weight: | 0.11 kg |
This B+B dew point controller with condensate formation is an electronic hygrostat which is used for detecting dew formation and beginning of condensation on objects such as pipes and windows.
With the innovative measuring principle and the use of a special sensor with logarithmic characteristics, it is possible to control closely to the dew point threshold without risking condensation. The dew point controller can be mounted directly and simply on pipes with the corresponding diameter. It is completely sealed so the electronics are optimally protected.
Typical areas of application
- For cooling ceilings to prevent condensation
- For indoor pools and shop display windows to keep the double glazing fog-free and prevent steaming-up
- In drinking water and industrial plants to detect „sweating“ of cold pipes
- In Hypermarkets, Concourses, Halls, Greenhouses and Storage facilities, to detect condensation formation on cold outdoor walls, steel doors, or to protect the stonework and masonry
- In switch cabinets or in machines, to detect condensation on sensitive electronic components
- For humidity and leakage detectors
- It can be integrated into alarm or warning systems ( by the relay / opener )
- In submersible pumps for detecting leakage
| Description: | Dew point controller |
|---|---|
| Measuring medium: | Ambient air (without admixtures) |
| Operating temperature: | 0...+60 °C |
| Humidity measuring principle: | Resistive dew sensor |
| Humidity measuring range: | 0...100% RH |
| Response time humidity: | approx. 30 s (when changing from 75% RH to condensation) |
| Switching characteristic: | Potential-free switching output (relay) 24 V AC, NO / NC contact selectable |
| Switching point: | 90% RH, ±4 % preset |
| Switching capacity: | 5A / 230 V AC; 5A / 30 V DC |
| Contact voltage: | 24 V AC |
| Contact resistance: | Closed: 100 Ω, open: > 1 MΩ |
| Switch display: | LED green (power); LED not lit (dry); LED red (condensation) |
| Condensation: | permitted |
| Condensation: | Permitted for a short time |
| Hysteresis: | approx. 4% |
| Pipe diameter: | Ø 28-35 mm |
| Dimensions: | (LxWxH) 65 x 60 x 42 mm (without mounting clamp, without cable) |
| Connection: | Push-in terminal 0.0509–1.31 mm² (16–30 AWG) |
| Output: | Switching relay |
| Operating current: | typ. 7 mA, max. 30 mA (relay active) |
| Operating voltage: | 24 V AC ±10%, 50 Hz or 24 V DC ±10% |
| Function check: | Rote Power LED leuchtet bei Betrieb |
| Protective filter: | Polyethylene sintered material |
| Type of protection: | IP65 |
| Weight: | 0.11 kg |
This B+B dew point controller with condensate formation is an electronic hygrostat which is used for detecting dew formation and beginning of condensation on objects such as pipes and windows.
With the innovative measuring principle and the use of a special sensor with logarithmic characteristics, it is possible to control closely to the dew point threshold without risking condensation. The dew point controller can be mounted directly and simply on pipes with the corresponding diameter. It is completely sealed so the electronics are optimally protected.
Typical areas of application
- For cooling ceilings to prevent condensation
- For indoor pools and shop display windows to keep the double glazing fog-free and prevent steaming-up
- In drinking water and industrial plants to detect „sweating“ of cold pipes
- In Hypermarkets, Concourses, Halls, Greenhouses and Storage facilities, to detect condensation formation on cold outdoor walls, steel doors, or to protect the stonework and masonry
- In switch cabinets or in machines, to detect condensation on sensitive electronic components
- For humidity and leakage detectors
- It can be integrated into alarm or warning systems ( by the relay / opener )
- In submersible pumps for detecting leakage
Similar articles
Other customers also bought
We generally offer standard shipping via DPD. You can also pick up your order yourself or ship with your own tracking number. You can select the option you prefer during the ordering process.
You find more information about this topic on our rights of withdrawal page.
You can pay with PayPal, credit card (VISA and MaserCard), payment in advance, Sofortüberweisung (direct banking) and in some cases invoice. You can find more information on the page shipping and payment.
Yes, at B+B we can manufacture customised items for you with a minimum order value of €500.00.