- Article name
- Digital humidity and temperature probe
- measurement category
- humidity and temperature
- Sensor
- Digital humidity and temperature sensor HYT271-S
- Humidity measuring range
- 0...100% RH
- Humidity accuracy
- ±2% RH at 23 °C
- Temperature measuring range
- -40...+125 °C
- Accuracy
- ±0.2 °C (at 0...60 °C)
- Resolution
- 14 Bit
- I²C address
- 0x28, 0x29 or 0x2A
- Tube length incl. filter
- 150 mm
- Tube diameter
- 12 mm
- Tube material
- Stainless steel 1.4571
- Protective filter
- Stainless steel 1.4404, pore size 45 µm, Ø 12 x 20mm
- Cable
- AWG28, PVC insulated, AD 5.0 mm
- Cable length
- 3000 mm
- Connection
- RJ12-connection plug
- Operating voltage
- 2.7...5.5 V DC
- Protection category
- IP65 (except thermocouple connector and sintered filter)
- Current consumption
- typ. <22 µA bt 1 Hz measuring rate, 850 µA maximal
- Output signal
- Digital, I²C
- Features
- For use with the HYTELOG Multisensor measuring system
- Weight
- 0.1338 kg
The innovative humidity and temperature probe uses a I²C-interface communication protocol. The probe is calibrated ex factory to a high measurement accuracy both for temperature (±0,2 °C) and humidity (±0,18 %RH) and an extensive temperature range up to 125 °C.
The humidity and temperature probe is ebcapsulated in a high quality stainless steel housing using a stainless steel sinter filter with pore size about 45 µm. the filter protects the sensors from mechanical damages and dirt and at the same time allows a relative rapid air circulation between the ambient air and the measurement chamber (good response time). The RJ12 Connector enables an easy and fast connection to our HYTELOG Multisensor interface. The digital I²C output signal can also be prcessed via a microcontroller (µC). The probe has standardly an I²C bus address 0x28. This can be changed with a µC or with the B+B I2C-USB interface adapter.
With the Hytelog humidity and temperature measuring system you have the option of connecting 3 sensors at the same time. The temperature or humidity sensors can be easily connected via the three RJ12 sockets. It only has to be considered that the sensors have different I²C addresses. When used with the Hytelog multisensor, only the addresses 0x28,0x29 and 0x2A are permitted.
Cable lengths of 10, 15, and 20 m are available under request.
Areas of application:
- Building technology
- Industrial measurement and control technology
- Climate monitoring and use in drying processores such as tea or tobacco
I²C interface
Communication corresponds to the usual I²C protocol. All technical specifications of the protocol can be found in the documentation "Serial" Interface of B + B. Log in conveniently in our download center and select "I²C communication ASIC": Download page .
Note:
Programming of customer-specific I²C address with article SHOP 0800 3000.